Reducers / RED-L

Low-Loss Reducer

Reducer with aerodynamic long-radius design minimizing pressure loss.

Technical Specifications

Pressure
150# - 2500#
Temperature
-196°C ~ +650°C
Size Range
4" x 2" - 36" x 18"
Materials
A234 WPB, 304/L, 316/L, A860 WPHY52/60
Standards
manufacturer's standard or customer drawing

Key Features

  • Minimal pressure loss
  • Aerodynamic body
  • Energy efficiency
  • Optimized flow path
  • Long radius transition
  • High performance

Applications

  • Power plants
  • Large pump systems
  • Compressor stations
  • High flow pipelines
  • Critical processes
  • Energy saving systems

Dimension Table

SizeLarge Outside Dia. (mm)Small Outside Dia. (mm)Thickness (mm)
4" x 2"114.360.36.02
6" x 4"168.3114.37.11
8" x 6"219.1168.38.18
12" x 8"323.9219.110.31
16" x 12"406.4323.912.70

Technical Notes

  • 01Provides energy savings.
  • 02Ideal for large flow systems.
  • 03Requires longer installation length.
  • 04More costly than standard reducers.

Low-Loss Reducer: grades, standards and selection notes

Low-Loss Reducer belongs to our Reducers range and is listed for sizes 4" x 2" – 36" x 18". Materials: A234 WPB (ASTM A234 carbon steel); 304/L, 316/L (austenitic stainless steel; L grades are low-carbon for welding, 316 adds molybdenum for chloride resistance); A860 WPHY52/60 (high-yield pipeline grade; the number is the minimum yield strength in ksi).

It uses a long, shallow cone, which lowers the pressure loss at the cost of a longer fitting. Cone angle and length are set by the design. It is supplied to manufacturer's standard or customer drawing. The temperature range given, −196°C – +650°C, applies depending on the material grade chosen.

The dimension table on this page lists 5 sizes from 4" x 2" to 16" x 12"; outside diameters at the large end run from 114.3 to 406.4 mm and the wall thickness in these rows from 6.02 to 12.70 mm. A butt-welding fitting takes the wall schedule of the pipe it is welded to, so the schedule is confirmed in the quotation.

Compared with the other types in this group: Concentric Reducer — common centreline; size range 1/2" x 1/4" – 48" x 24"; standards ASME B16.9, MSS SP-75, EN 10253, DIN 2616; temperature −196°C – +815°C. Eccentric Reducer — one flat side, offset centrelines; size range 2" x 1" – 36" x 18"; standards ASME B16.9, MSS SP-75, EN 10253, DIN 2616. Sudden Reducer — abrupt step, short body, higher pressure loss; size range 1" x 1/2" – 24" x 12"; temperature −45°C – +400°C. Multi-Stage Reducer — several reduction steps for large ratios; size range 6" x 2" – 42" x 14"; temperature −196°C – +815°C.

To request a quotation for Low-Loss Reducer, give the size (for example 4" x 2"), the wall thickness or schedule, the material (for example A234 WPB), the standard (manufacturer's standard or customer drawing) and the quantity. Material is supplied with an EN 10204 3.1 inspection certificate; third-party inspection by bodies such as SGS, Bureau Veritas or TÜV is arranged on request. Whether the size can be supplied from stock, the minimum quantity and the lead time are stated in the quotation, which is sent within 24 hours.

What is a pipe reducer?

A reducer is a butt-weld fitting that joins two pipes of different diameters.

Reducers: guide and FAQ